SnapCap guide for M110 and E210 series
SnapCap guide for M110 and E210 series
SnapCap guide for M110 and E210 series
Introduction
![](https://cdn.lantronix.com/downloads/mobility/images/snapcap.jpg)
General setup
You can follow this diagram to connect the RS-485 cable to the SnapCap:![](https://cdn.lantronix.com/downloads/mobility/images/esnapcap-1.png)
- B = Data-
- A = Data+
- G = GND
Setup for M110
Firstly, connect the RS-485 in the SnapCap as shown in General Setup and connect the SnapCap to the RS-232 input in the M110 device. Finally, you are able to communicate via RS-485 with the device.![](https://cdn.lantronix.com/downloads/mobility/images/snip.png)
Setup for E210
Firstly, download the file snapcap.sh and copy it in /etc/init.d/ (view Copy files with SCP)snapcap.sh
Then, enter via SSH to the router (view SSH access) and execute the following code: snapcap.sh
Version: 1 – File size: 1 KB
Version: 1 – File size: 1 KB
chmod u+x /etc/init.d/snapcap.sh
/etc/init.d/snapcap.sh enable
Reboot the device, connect the RS-485 in the SnapCap as shown in General Setup and connect the SnapCap to the RS-232 input in the E210 device. Then, go to Services>Serial and configure the Data Send Configuration as shown in the image bellow. ![](https://cdn.lantronix.com/downloads/mobility/images/e210-snap0.png)
![](https://cdn.lantronix.com/downloads/mobility/images/e210-snap2.png)
![](https://cdn.lantronix.com/downloads/mobility/images/e210-snap1.png)
[Originally Published On: 09/23/2019 11:22 AM]