SnapCap guide for M110 and E210 series
SnapCap guide for M110 and E210 series
SnapCap guide for M110 and E210 series
Introduction

General setup
You can follow this diagram to connect the RS-485 cable to the SnapCap:
- B = Data-
- A = Data+
- G = GND
Setup for M110
Firstly, connect the RS-485 in the SnapCap as shown in General Setup and connect the SnapCap to the RS-232 input in the M110 device. Finally, you are able to communicate via RS-485 with the device.
Setup for E210
Firstly, download the file snapcap.sh and copy it in /etc/init.d/ (view Copy files with SCP)snapcap.sh
Then, enter via SSH to the router (view SSH access) and execute the following code: snapcap.sh
Version: 1 – File size: 1 KB
Version: 1 – File size: 1 KB
chmod u+x /etc/init.d/snapcap.sh
/etc/init.d/snapcap.sh enable
Reboot the device, connect the RS-485 in the SnapCap as shown in General Setup and connect the SnapCap to the RS-232 input in the E210 device. Then, go to Services>Serial and configure the Data Send Configuration as shown in the image bellow. 


[Originally Published On: 09/23/2019 11:22 AM]
, multiple selections available,
Related content
E210 - How to use serial port RS-232
E210 - How to use serial port RS-232
More like this
ETS8UF-ETS16UF-EPS4UF RJ12 Serial Pinouts
ETS8UF-ETS16UF-EPS4UF RJ12 Serial Pinouts
More like this
Pinouts for XPress-DR and XPress-DR-IAP RJ45 serial port to go to a DB9 Connector
Pinouts for XPress-DR and XPress-DR-IAP RJ45 serial port to go to a DB9 Connector
More like this
Pinouts and wiring diagrams for current Lantronix serial adapters, 200.2066A, 200.2067A, 200.2069A, 200.2070A, 200.2071, 200.2072, 200.2073, 200.2074 & ADP010104-01
Pinouts and wiring diagrams for current Lantronix serial adapters, 200.2066A, 200.2067A, 200.2069A, 200.2070A, 200.2071, 200.2072, 200.2073, 200.2074 & ADP010104-01
More like this
Step-by-step SLC and SLB configuration
Step-by-step SLC and SLB configuration
More like this
RJ45 Serial Pinouts and cables for Lantronix console and device servers
RJ45 Serial Pinouts and cables for Lantronix console and device servers
More like this