Pinouts for XPress-DR and XPress-DR-IAP RJ45 serial port to go to a DB9 Connector
Pinouts for XPress-DR and XPress-DR-IAP RJ45 serial port to go to a DB9 Connector
What are the pinouts to go from the RJ45 serial port of an XPress-DR or XPress-DR-IAP to the DB9 Serial port of my device?
Here are the pinouts for a DTE and DCE device:
To connect to a male DB9 DTE (e.g. the Com port on a PC):
XPress-DR
RJ45 DB9F Signal
N/A 8-------------------
RTS 7-------------------8 CTS
CTS 6-------------------7 RTS
GND 5-------------------5 Signal Ground
TX 4-------------------2 RX
RX 3-------------------3 TX
DTR 2-------------------6 DSR (Possibly DCD depending on customers device)
N/A 1-------------------
To connect to a female DB9 DCE:
XPress-DR
RJ45 DB9M Signal
N/A 8-------------------
RTS 7-------------------7 RTS
CTS 6-------------------8 CTS
GND 5-------------------5 Signal Ground
TX 4-------------------2 TXD
RX 3-------------------3 RXD
DTR 2-------------------4 DTR
N/A 1-------------------