The text based Setup page on my device server requires a hexidecimal number for the Connect Mode. What hex values are valid for the Connect Mode? I see the User Guide shows which bits to set, with a few example hex values. Is there an easier way?


Connect Mode defines how the Cobos based Device Servers make a connection, and how they react to incoming connections over the network. The chart below with lists all valid connect modes for Cobos based devices.

Values not listed in this table should be avoided.

Valid Standard Connection Modes

Mode

Accept Incoming Connection

Response

Startup

Datagram Type

Modem Mode

 

00

Never

Nothing

No Active

 

 

 

01

Never

Nothing

With Any Character

 

 

 

02

Never

Nothing

With Active DTR

 

 

 

03

Never

Nothing

With CR (0x0D) only

 

 

 

04

Never

Nothing

Manual Connection

 

 

 

05

Never

Nothing

Autostart

 

 

 

06

Never

Nothing

Modem Mode

 

With Echo

 

0C

Never

Nothing

Directed UDP

Directed UDP

 

 

10

Never

Character

No Active

 

 

 

11

Never

Character

With Any Character

 

 

 

12

Never

Character

With Active DTR

 

 

 

13

Never

Character

With CR (0x0D) only

 

 

 

14

Never

Character

Manual Connection

 

 

 

15

Never

Character

Autostart

 

 

 

16

Never

Character

Modem Mode

 

No Echo

 

1C

Never

Directed UDP

Directed UDP

 

 

 

40

With DTR

Nothing

No Active

 

 

 

41

With DTR

Nothing

With Any Character

 

 

 

42

With DTR

Nothing

With Active DTR

 

 

 

43

With DTR

Nothing

With CR (0x0D) only

 

 

 

44

With DTR

Nothing

Manual Connection

 

 

 

45

With DTR

Nothing

Autostart

 

 

 

46

With DTR

Nothing

Modem Mode

 

With Echo

 

4C

With DTR

Nothing

Directed UDP

Directed UDP

 

 

50

With DTR

Character

No Active

 

 

 

51

With DTR

Character

With Any Character

 

 

 

52

With DTR

Character

With Active DTR

 

 

 

53

With DTR

Character

With CR (0x0D) only

 

 

 

54

With DTR

Character

Manual Connection

 

 

 

55

With DTR

Character

Autostart

 

 

 

56

With DTR

Character

Modem Mode

 

No Echo

 

5C

With DTR

Directed UDP

Directed UDP

 

 

 

C0

Unconditional

Nothing

No Active

 

 

 

C1

Unconditional

Nothing

With Any Character

 

 

 

C2

Unconditional

Nothing

With Active DTR

 

 

 

C3

Unconditional

Nothing

With CR (0x0D) only

 

 

 

C4

Unconditional

Nothing

Manual Connection

 

 

 

C5

Unconditional

Nothing

Autostart

 

 

 

C6

Unconditional

Nothing

Modem Mode

 

With Echo

 

CC

Unconditional

Nothing

Directed UDP

Directed UDP

 

 

D0

Unconditional

Character

No Active

 

 

 

D1

Unconditional

Character

With Any Character

 

 

 

D2

Unconditional

Character

With Active DTR

 

 

 

D3

Unconditional

Character

With CR (0x0D) only

 

 

 

D4

Unconditional

Character

Manual Connection

 

 

 

D5

Unconditional

Character

Autostart

 

 

 

D6

Unconditional

Character

Modem Mode

 

No Echo

 

DC

Unconditional

Character

Directed UDP

Directed UDP

 

 


Values not listed above are not supported and should not be used.