The text based Setup Mode of my device server requires a hex number for the Interface Mode. What are the valid hex values for Interface Mode? The User Guide only shows which bits to set with a few examples. Is there an easier way?


Here is a table of Valid Interface Modes.


Do not use Hex mode values not listed in this table

HEX Stop Bit Parity Char Bit RS Type
48 1 None 7 232
49 1 None 7 422/485
4B 1 None 7 485 2-wire
4C 1 None 8 232
4D 1 None 8 422/485
4F 1 None 8 485 2-wire
58 1 Odd 7 232
59 1 Odd 7 422/485
5B 1 Odd 7 485 2-wire
5C 1 Odd 8 232
5D 1 Odd 8 422/485
5F 1 Odd 8 485 2-wire
78 1 Even 7 232
79 1 Even 7 422/485
7B 1 Even 7 485 2-wire
7C 1 Even 8 232
7D 1 Even 8 422/485
7F 1 Even 8 485 2-wire
C8 2 None 7 232
C9 2 None 7 422/485
CB 2 None 7 485 2-wire
CC 2 None 8 232
CD 2 None 8 422/485
CF 2 None 8 485 2-wire
D8 2 Odd 7 232
D9 2 Odd 7 422/485
DB 2 Odd 7 485 2-wire
DC 2 Odd 8 232
DD 2 Odd 8 422/485
DF 2 Odd 8 485 2-wire
F8 2 Even 7 232
F9 2 Even 7 422/485
FB 2 Even 7 485 2-wire
FC 2 Even 8 232
FD 2 Even 8 422/485
FF 2 Even 8 485 2-wire