The text based Setup Mode of my device server requires a hex number for the Interface Mode. What are the valid hex values for Interface Mode? The User Guide only shows which bits to set with a few examples. Is there an easier way?


Here is a table of Valid Interface Modes.


Do not use Hex mode values not listed in this table


HEXStop BitParityChar BitRS Type
481None7232
491None7422/485
4B1None7485 2-wire
4C1None8232
4D1None8422/485
4F1None8485 2-wire
581Odd7232
591Odd7422/485
5B1Odd7485 2-wire
5C1Odd8232
5D1Odd8422/485
5F1Odd8485 2-wire
781Even7232
791Even7422/485
7B1Even7485 2-wire
7C1Even8232
7D1Even8422/485
7F1Even8485 2-wire
C82None7232
C92None7422/485
CB2None7485 2-wire
CC2None8232
CD2None8422/485
CF2None8485 2-wire
D82Odd7232
D92Odd7422/485
DB2Odd7485 2-wire
DC2Odd8232
DD2Odd8422/485
DF2Odd8485 2-wire
F82Even7232
F92Even7422/485
FB2Even7485 2-wire
FC2Even8232
FD2Even8422/485
FF2Even8485 2-wire




[Originally Published On: 08/04/2006 04:19 PM]