A functioning SLC or SLB should generally be updated using the upgrade patch.  CLICK HERE for  Click here for the FAQ on upgrading via the patch.

...

Boot 1.1.5.L6 (Jan 25 2008 - 17:20:46) <--- First boot message. Type x15 within 10 seconds
Board: X15-0
CPU: Au1500, id: 0x02, rev: 0x02
DRAM: 128 MB
Flash: 4 MB
ethaddr = 00:80:a3:89:0b:6d
eth1addr = 00:80:a3:89:0b:6e
Bus 0: OK
Device 0: Model: SanDisk SDCFJ-256 Firm: HDX 2.27 Ser#: 1171602L02V58092
Type: Removable Hard Disk
Capacity: 245.0 MB = 0.2 GB (501760 x 512)  <---CF capacity.  This one is for a 256MB CF.
Net: Au1X00 ethernet
Lantronix
lantronix>

If your SLC or SLB does not have a 512MB CF, the v6.1.0.0 firmware cannot be loaded as an image.

In those cases, you must load the newest firmware version prior to v6.1.0.0, then patch the unit to v6.1.0.0.

If your SLC or SLB does have a 512MB CF, and has never run firmware version v6.1.0.0, and you have no alternative but to load the firmware using the image file, the best course of action would be to load the newest firmware prior to v6.1.0.0 via the image copy, then patch it to v6.1.0.0.

CLICK HEREclick here for an FAQ on imaging the SLC or SLB with the release prior to v6.1.0.0.  Note that v6.1.0.0 will not run on unit with a 128MB CF.

The only situation in which the v6.1.0.0 or higher image file would be loaded directly onto the SLC or SLB would be:

...

The SLB runs the same firmware, so the SLC image file can be used on either model.  Once you have the image file, you can use the procedure shown in THIS this FAQ to load it.


...