Using UDP Configuration In CoBos Products To Reply To The Last Host Requesting Data

How Do I Configure UDP In My CoBos Product To Reply To The Last Host Requesting Data?


To configure the CoBos product for using UDP in this scenario, connect the correct type of serial cable (either modem or null modem) from a com port on your PC to the serial port on the CoBos product. See the serial pinout information in the User Guide to determine if you need a modem cable or a null modem cable for your specific CoBos product.

Set your emulation port settings to 9600, 8 data bits, no parity, one stop bit & no flow control.

Once the emulation session is started, power cycle the CoBos product while holding the "x" key (lower case) on your keyboard. When you see the information about the product hit enter key to access the menu. Do this within 3 seconds or it will time out and your will need to repeat the process.

You will be prompted with the menu selections.

Change Setup:
0 Server
1 Channel 1
5 Expert
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit Your choice ?

  • Select 1, for the channel 1 configuration and hit enter.
  • Baudrate (9600) ? Type in the baud rate you need to match your serial device (default is 9600), then enter
  • I/F Mode (4C) ? Type in the hex value to represent the serial protocol, data bits, parity & stop bits (default is 4C for RS232, 8 data bits, no parity, 1 stop bit), then enter
  • Flow (00) ? Type in the flow control value (default - 00 is none, 01 is software, 02 is hardware & 05 is software pass thruough), then enter
  • Port No (10001) ? Type in the port number you want (default is 10001), then enter
  • Connect Mode (C0) ? Type in CC, then enter
  • Datagram Type (00) ? Type in 01, then enter

  • Send as Broadcast (N) ? N, then enter
  • Remote IP Address : Type in 0.0.0.0 and ignore what you see in parenthesis, then enter
  • Remote Port (0) ? Type in 0, and ignore what you see in parenthesis, then enter
  • Pack Cntrl (00) ? Type in 0, then enter
  • SendChar 1 (00) ? Type in 0, then enter
  • SendChar 2 (00) ? Type in 0, then enter
Change Setup:
0 Server
1 Channel 1
5 Expert
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit Your choice ?
  • Type 9 for save and exit, then enter.

When your application initiates the communication to the CoBos product the CoBos product will communicate back to the last host that started that session. The CoBos product will use the IP address and port number of the host that started the UDP session.