What is the procedure to upgrade an SLC/SLC8000 or SLB using HTTPS?
Note: Firmware versions up to and including v5.3b cannot find the slcupdate*.tgz upgrade file on a Windows PC unless it is in C:\. Later versions can load the firmware from any directory.
If you're running 5.3b or earlier ut the upgrade file into C:\ on a Windows PC.
On the Maintenance Page, select HTTPS for Load Firmware (this enables ‘Upload File’ link to the right)
Click Upload File link, then browse to select FW, click ‘Upload File’ button and after upload completed click ‘Close Window’ button.
This will upload FW to SLC. The upgrade has not yet been installed.
At this stage, the upload FW filename should appear in the ‘Firmware Filename’ text box.
Enter the Checksum Key
Click Update Firmware Check box
Click the ‘Apply’ button
This will start the upgrade process. Open the Status window to monitor the upgrade messages.
On a single-bank system the SLC will automatically reboot at the end of the upgrade process.
On a dual-bank system the unused bank will be upgraded. A manual reboot is required to boot from the newly upgraded bank