Along with being dual boot, SLCx-02 models must be running firmware version v5.4 before applying the v6.1.0.0 patch. If your SLCx-02 is running firmware older than v5.2a, you must update it to v5.2a prior to updating it to v5.4. click Click here for instructions on updating it to v5.2a.
...
5.4 for SLCx-02 (with PC Card slots):
File | Comment |
SLCx v5.4 Firmware for SLCx-02 and earlier (with PC Card slots) - ZIP archive | |
v5.4 Firmware Release notes (includes Update Key) | Right Click and "Save as..." |
...
IMPORTANT - Do not proceed with an update of an SLCx-02 model (model with PC Card Slots) if the units have not been updated to v5.4 and have dual boot banks, as described here.
...
6.1.0.0:
IMPORTANT, READ THIS BEFORE PROCEEDING - If your SLC-02 is running v5.4 on both boot banks, first download and install the patch file for v6.1.0.0 using the following links.
File | Comment |
V6.1.0.0 Firmware for SLCx-02 and SLCx-03 (running v5.4 or v5.5, minimum, respectively) - ZIP archive | |
V6.1.0.0 Firmware Release notes (includes Update Key) | Right Click and "Save as..." |
MD5 checksum file (Update Key) | Right Click and "Save as..." |
...
If your SLC is running 6.1.x firmware on both banks you can directly load v6.2.0.0 using the following links. If only one bank has 6.1.0.0 or higher installed, and it is the "current" bank, you will need to reboot to the other bank so that you are upgrading the 6.x bank. You can do this on the Maintenance>Firmware/Config page. Attempting to load 6.2.0.0 into a bank with 5.x firmware will fail.
File | Comment |
V6.2.0.0 Firmware for SLCx-02 and SLCx-03 (running v6.1.0.0 minimum) - ZIP archive | |
V6.2.0.0 Firmware Release notes (includes Update Key) | Right Click and "Save as..." |
MD5 checksum file (Update Key) | Right Click and "Save as..." |
...